SU-5 and CU-4E with one or more 0-10V Drivers (02693-06)

Connections between 0-10V Drivers with a CU-4E and any SU-5 Sensor. Download line diagram PDF.

Line_Diagram_-_SU5E-CU4E-FMH_-_Generic_Driver_s__Wiring_-_93-02693-06.jpg

Recommended article:

Downloads:  

SU-5 with CU-4D with one or more DALI Drivers (02945-02)

Connections between a single or multiple DALI drivers and Control Unit DALI (CU-4D-FM). Download PDF version of the line diagram.

mceclip0.png

Recommended articles:

 Downloads:

SU-5 with DALI Drivers and External PSU (03172-02)

Connections between a single or multiple DALI drivers and External Power Supply Unit (PSU) connected to an Enlighted Gen 5 (SU-5) sensor.

Download a PDF version of the line diagram.

Line_Diagram_-__2-wire__SU5_w-DALI_Driver_s__and_External_PSU_-_93-03172-02.jpg

 

Downloads:

SU-5 and CU-4E (NME) with one or more 0-10V Drivers (03155-02)

Connections between one or more 0-10V Driver with a Control Unit Nipple Mount External (CU-4E NME)  and any SU-5 Sensor. Download the line diagram PDF.

Line_Diagram_-_SU5E-CU4E-NME_-_Generic_Driver_s__Wiring_-_93-03155-02.jpg

Recommended articles:

Downloads:  

SU-5 and CU-4E (NMI) with one or more 0-10V Drivers (03156-02)

Connections between one or more 0-10V Driver with a Control Unit Nipple Mount Internal (CU-4E NMI)  and any SU-5 Sensor. Download the line diagram PDF.

Line_Diagram_-_U5E-CU4E-NMI_-_Generic_Driver_s__Wiring_-_93-03156-02.jpg

Recommended article:

Downloads:  

SU-5 and CU-4E (NMx) with Contactor (03158-03)

Connections using a Control Unit Nipple Mount External (NME is shown) or NMI and Contactor with a Gen 5 Sensor.

Download a PDF version of the line diagram.

Line_Diagram_-_CU-4E-NMx_w-SU5_w-Contactor_-_93-03158-03.jpg

Recommended articles:

Downloads:

SU-5 and CU-4E with Contactors (03095-02)

The line diagram shows the connections between an Enlighted Gen 5 sensor, Control Unit with a third-party contactor. This solution can be used for exterior outdoor lighting with an Astro clock. If the circuit control load exceeds, you may need a  contactor relay to control larger loads.  However, note that energy metering is not possible with this application as the supply goes directly through the contactor to the load. When designing solutions for exterior outdoor lighting, the Ruggedized sensor is IP rated for better performance outdoors. The sensor should always be visible and never contained within a metal enclosure. The total length of the sensor cable must be 300 feet or less.

The Plugload controller Plug Load Controller with Contactor (02624-02) does not support Astro clock, nor is it rated for outdoor use; however, energy metering is possible. Hence, use the sensor, CU combination with the contactor relay shown below, or the Plug Load Controller, depending on the application.

Download the line diagram PDF.

Line_Diagram_-_Large_Load_-_SU5-CU4_-_w-Contactor_s__-_93-03095-02.png

Downloads:

SU-5 and CU-4E with Contactors and Photocell (03185-01)

The line diagram shows the connections between an Enlighted Gen 5 (SU-5) Micro sensor (SU-5E), High Bay (SU-5S), or Ruggedized (SU-5S-xRx) sensor with Contractor along with a photocell and Enlighted's Control Unit (CU-4E).  

Download the Line Diagram PDF.

Line_Diagram_-_Large_Load_-_SU5-CU4_-_w-Contactor_s__and_Photocell_-_93-03185-01.png

Downloads: